Our Products
Microporous Filter Membrane for Water Testing Lab Made in China
  • Worldwide Shipping
  • Quality Assured
  • OEM Available
Engineering Equipment

Microporous Filter Membrane for Water Testing Lab

Download PDF
Need a custom quote? Contact us →

6431

Description

Microporous Filter Membrane for Water Testing Lab

 

Specification

Usage

Mainly used for microbial detection and capture, trace element analysis, bioengineering in medical research and diagnosis, biochemical analysis, etc.

Microporous Filter Membrane:

The microporous filter membrane has hydrophilicity, weak acid resistance and high protein binding capacity.

Pore size

In specific experiments, appropriate pore size membrane filters should be selected based on your filtration purpose and experimental needs.

0.8 μm and above: can filter impurities of larger particles or difficult to treat or turbid samples for pre-treatment, and then select the corresponding membrane filters for filtration after pre-treatment.

0.22 μm: It can remove 99.99% of bacteria and microorganisms, meet the sterilization requirements of GMP or pharmacopoeia, and can also remove extremely fine particles in samples and mobile phases.

0.1 μm: Able to remove Mycoplasma from the sample.

0.45μm: It can filter out most bacteria and microorganisms, and can meet the general chromatographic requirements for conventional samples with equal flow.

This membrane filters is generally used as a terminal filtration membrane. If there are many impurities in the solution, it is recommended to use a large-diameter filter material for pre filtration first to avoid frequent blockage of the membrane filters.

This membrane filters generally has a pressure resistance of 0-0.2Mpa, and there may be some wrinkles on the membrane surface, which is a normal phenomenon.

This microporous filter membrane should be stored in a cool place, and it is not recommended to store it for too long (such as more than a year) to avoid oxidation and contact with open flames.

This membrane filters is suitable for solutions with a pH of 5-9 and is not suitable for filtering organic solvents and strong acid-base solutions. If you need to filter organic solvents and corrosive solutions, please use our company's organic series microporous membrane filters.

 

Usage

(1) This microporous filter membrane is recommended to place the membrane filters flat in a clean container before use, soak it in distilled water at around 40?, and let it soak for more than 4 hours. Before use, soak it again with an appropriate amount of warm distilled water.

(2) If the usage requirements are not particularly high, the above steps can be omitted, but it will have an impact on the filtration speed and the flexibility of the membrane filters, because the water based cellulose membrane after soaking treatment will have better flexibility, not easy to break, and the flow rate will also be faster.

(3) After the above steps, the cleaned membrane filters (wet) can be loaded into a suitable filter to prevent surrounding leakage, and the filtration operation can be carried out. Due to the fine pore size of the mixed fiber membrane, the flow rate of atmospheric filtration is slower. Vacuum pump negative pressure filtration or air pump pressure filtration can be used. When the pressure gauge rapidly rises to 0.4-0.6 Ma, it is recommended to stop working and replace the membrane filters.

Why Buy Microporous Filter Membrane for Water Testing Lab from Engineering Lab China

As leading microporous filter membrane for water testing lab manufacturers, suppliers & exporters in China, Engineering Lab China combines factory-direct pricing, strict quality control and reliable worldwide shipping. Every Microporous Filter Membrane for Water Testing Lab is built in-house in Guangzhou City to deliver dependable performance for engineering training and teaching environments.

Direct from the Factory

We manufacture every Microporous Filter Membrane for Water Testing Lab at our own facility in Guangzhou, China. No middlemen — you get factory pricing on Engineering Laboratory Trainer Kits, Training Charts and Educational Equipment.

Built for Real Classrooms

Every Microporous Filter Membrane for Water Testing Lab passes a strict outward quality check before dispatch, so it stands up to daily use in Industrial Training Institutions, Engineering Colleges & Polytechnics.

Ships to 40+ Countries

From a single trainer kit to a full lab tender, our team manages packaging and prompt international delivery so your Microporous Filter Membrane for Water Testing Lab arrives on schedule, anywhere in the world.

Bulk Supply & Custom Orders

Microporous Filter Membrane for Water Testing Lab Manufacturers, Suppliers & Exporters in China

EngineeringLabChina is a leading microporous filter membrane for water testing lab manufacturers, microporous filter membrane for water testing lab suppliers & exporters in China. Whether you need a single unit for a lab refresh or a complete tender for a polytechnic, we handle Engineering, Procurement, Installation and Commissioning under one roof.

We accept Wire or Telegraphic Transfer / Letter of Credit. Shipping is based on consignment size — contact us with your requirement for an accurate quote.

How to Order

  1. 01
    Send Enquiry

    Share quantity, destination country and any custom specs for the Microporous Filter Membrane for Water Testing Lab.

  2. 02
    Receive Quote

    Our team replies with factory pricing, lead time and shipping options within 24 hours.

  3. 03
    Production & QC

    We manufacture in Guangzhou, run a quality check and prepare export-ready packaging.

  4. 04
    Worldwide Dispatch

    Consignment dispatched by your preferred mode — sea, air or courier — to your door.

Manufacturing & Export Specialisations

Full product category index — manufactured in Guangzhou, exported worldwide.

View All Products
Support