Chemicals Oxygen Demand Apparatus for Water Testing Lab

 

Specification

The COD stands out for its dual-range measurement and interference-free optical system, making this chemical oxygen demand apparatus essential for environmental labs and wastewater treatment plants. This chemical oxygen demand apparatus, the COD, is a professional water quality testing instrument designed for rapid and accurate COD measurement in surface water, wastewater and industrial effluents. Equipped with a self-calibration function and large data storage, the COD ensures consistent performance, solidifying its role as a trusted chemical oxygen demand apparatus for water quality assessment.

 

Features

Measure high-range and low-range COD water samples, supporting both dish and tube colorimetry;

Independent dual-path, interference-free system for direct concentration reading, high accuracy, long life, and enhanced stability;

Rapidly and accurately measure COD in surface water, reclaimed water, municipal sewage, and industrial wastewater;

Built-in infrared and USB dual data transmission interfaces for data transfer via a computer cable or long-distance infrared connection;

Built-in printer for printing current data and all stored historical data;

Utilizing a self-designed non-metallic housing, the instrument is aesthetically pleasing;

Intuitive menu navigation and a 3.5-inch color LCD screen with user-friendly operation prompts make it easier to use;

The instrument features a self-calibration function that calculates and stores curves based on standard samples, eliminating the need for manual curve creation;

Flexible switching between large and small font display modes for clearer data display and more detailed parameters;

Supports historical data storage and viewing, capable of storing 12,000 data records;

 

Host Parameters

Measurement Range  (20~10000) mg/L (segmented)           (2~150)mg/L

COD concentration ≤ 500 mg/L, error ≤ ±8% Error ≤ ±8%

Minimum Detection Limit      0.1mg/L

Indication Error           COD concentration > 50 mg/L, error ≤ ±5%;

Chlorine Interference Resistance        [CL-]?1000mg/L (no effect) [CL-]?4000mg/L (optional)

Light Source Lifetime  100,000 hours

Power Supply  220V

Data Storage    12,000

Repeatability   ≤±3%

Stability           ?0.005A/20min

Batch Sample Processing        16 water samples

Measurement Time    20 minutes

Number of Curves       180 bars

Digestion instrument parameters

Display Mode  Color LCD (320*240 resolution)

Data Communication Port      USB/Infrared (optional)

Colorimetric Method  Cuvettes and tubes

Digestion temperature            165°C ± 0.5°C

Digestion time 10/15 minutes (optional)

Digestion time error   ≤ ±2°C

Timing range   1 minute - 96 hours

Timer switches            3

Timing accuracy          0.2 seconds/hour

Temperature indication error ≤ ±2°C

Temperature field uniformity ≤ 2°C

Power supply   AC220V ±10%/50Hz

Why Buy Chemicals Oxygen Demand Apparatus for Water Testing Lab from Engineering Lab China

As leading chemicals oxygen demand apparatus for water testing lab manufacturers, suppliers & exporters in China, Engineering Lab China combines factory-direct pricing, strict quality control and reliable worldwide shipping. Every Chemicals Oxygen Demand Apparatus for Water Testing Lab is built in-house in Guangzhou City to deliver dependable performance for engineering training and teaching environments.

Direct from the Factory

We manufacture every Chemicals Oxygen Demand Apparatus for Water Testing Lab at our own facility in Guangzhou, China. No middlemen — you get factory pricing on Engineering Laboratory Trainer Kits, Training Charts and Educational Equipment.

Built for Real Classrooms

Every Chemicals Oxygen Demand Apparatus for Water Testing Lab passes a strict outward quality check before dispatch, so it stands up to daily use in Industrial Training Institutions, Engineering Colleges & Polytechnics.

Ships to 40+ Countries

From a single trainer kit to a full lab tender, our team manages packaging and prompt international delivery so your Chemicals Oxygen Demand Apparatus for Water Testing Lab arrives on schedule, anywhere in the world.

Bulk Supply & Custom Orders

Chemicals Oxygen Demand Apparatus for Water Testing Lab Manufacturers, Suppliers & Exporters in China

EngineeringLabChina is a leading chemicals oxygen demand apparatus for water testing lab manufacturers, chemicals oxygen demand apparatus for water testing lab suppliers & exporters in China. Whether you need a single unit for a lab refresh or a complete tender for a polytechnic, we handle Engineering, Procurement, Installation and Commissioning under one roof.

We accept Wire or Telegraphic Transfer / Letter of Credit. Shipping is based on consignment size — contact us with your requirement for an accurate quote.

How to Order

  1. 01
    Send Enquiry

    Share quantity, destination country and any custom specs for the Chemicals Oxygen Demand Apparatus for Water Testing Lab.

  2. 02
    Receive Quote

    Our team replies with factory pricing, lead time and shipping options within 24 hours.

  3. 03
    Production & QC

    We manufacture in Guangzhou, run a quality check and prepare export-ready packaging.

  4. 04
    Worldwide Dispatch

    Consignment dispatched by your preferred mode — sea, air or courier — to your door.

Manufacturing & Export Specialisations

Full product category index — manufactured in Guangzhou, exported worldwide.

View All Products
Support